Warehouse relamping with equal lighting values and equal number of light points
DM 100W vs REFLECTOR 250W JM
Industrial warehouse of 50x50m and 6m height. The current installation includes 20 luminaires at a
height of 5m from the ground.
Reflections: ceiling 30%, walls 30%, floors 10%. Height of the work surface at ±0,8m.
The simulation shows the effects of replacing the current halogen lights (250W JM reflector) with the same number of 100W DM series LED projectors maintaining the ground illuminance value of 100lux as required by the UNI EN 12464 standard (lighting requirements for warehouses, minimum storage areas 100 lux).
LUMINAIRES NUMBER
20
ILLUMINANCE VALUES
110 lux
TOTAL CONSUMPTION
Reflector 250W JM: 5,4 KWh
DM 100W Series: 2KWh
Differenza:-62,9%
ADJUSTMENT MODE
Reflector 250W JM: single ignition, no power regulation
DM 100W Series: 1-10V Dimming
LIFETIME
Reflector 250W JM: 8.000h
DM 100W Series: L70B20 50.000h
Difference: +42.000h
Gas station relamping stazione di servizio with equal lighting values
CES-J 120W vs REFLECTOR 2X54W HF T5
Gas station 20x50m and 7,4m high. The current installation foresees 35 luminaires at a height of 7m.
Reflections: ceiling 70%, walls 50%, floors 20%. Height of the work surface at zero level.
The simulation shows the effects of a replacement of the current halogen lights (2x54W HF T5 reflectors) with a number of 120W CES-J projectors such as to maintain the ground illuminance value of 150lux as required by the UNI EN 12464 standard.
Number of LED projectors needed: 18 CES-J from 120W.
LUMINAIRES NUMBER
Reflectors HF T5 2x54W: 35
CES-J 120W Series: 18
Difference: -17
ILLUMINANCE VALUES
Reflectors HF T5 2x54W: 162lux
CES-J 120W Series: 184lux
TOTAL CONSUMPTION
Reflector HF T5 2x54W: 4 KWh
CES-J 120W Series: 2,13KWh
Difference: -46,75%
ADJUSTMENT MODE
Reflector HF T5 2x54W: single ignition, no power regulation
CES-J 120W Series: Dimming 1-10V
LIFETIME
Reflector HF T5 2x54W: 30.000h
CES-J 120W Series: L70B20 50.000h
Difference: +20.000h