{"id":5517,"date":"2019-01-14T09:16:48","date_gmt":"2019-01-14T09:16:48","guid":{"rendered":"https:\/\/www.luxi.lighting\/case-study-relamping\/"},"modified":"2019-01-14T09:16:49","modified_gmt":"2019-01-14T09:16:49","slug":"case-study-relamping","status":"publish","type":"page","link":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/","title":{"rendered":"Case Study: Relamping"},"content":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/4&#8243;][vc_column_text]<\/p>\n<h2>Warehouse relamping with equal lighting values and equal number of light points<\/h2>\n<p>[\/vc_column_text]<div class=\"eut-empty-space eut-height-1x\" style=\"\"><\/div>[vc_column_text]<\/p>\n<p style=\"text-align: left;\"><a href=\"https:\/\/www.luxi.lighting\/en\/?p=5116\" target=\"_blank\" rel=\"noopener\">DM 100W<\/a> vs REFLECTOR 250W JM<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]Industrial warehouse of 50x50m and 6m height. The current installation includes 20 luminaires at a<br \/>\nheight of 5m from the ground.<\/p>\n<p>Reflections: ceiling 30%, walls 30%, floors 10%. Height of the work surface at \u00b10,8m.<\/p>\n<p>The simulation shows the effects of replacing the current halogen lights (250W JM reflector) with the same number of <a href=\"https:\/\/www.luxi.lighting\/en\/?p=5116\" target=\"_blank\" rel=\"noopener\">100W DM series<\/a> LED projectors maintaining the ground illuminance value of 100lux as required by the UNI EN 12464 standard (lighting requirements for warehouses, minimum storage areas 100 lux).[\/vc_column_text][\/vc_column][\/vc_row][vc_row bg_type=&#8221;image&#8221; bg_image=&#8221;5484&#8243; color_overlay=&#8221;dark&#8221; opacity_overlay=&#8221;50&#8243; font_color=&#8221;#ffffff&#8221;][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">LUMINAIRES NUMBER<\/p>\n<p style=\"text-align: center;\">20<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">ILLUMINANCE VALUES<\/p>\n<p style=\"text-align: center;\">110 lux<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">TOTAL CONSUMPTION<\/p>\n<p style=\"text-align: center;\">Reflector 250W JM: 5,4 KWh<br \/>\nDM 100W Series: 2KWh<\/p>\n<p style=\"font-size: 18px; text-align: center;\">Differenza:<strong>-62,9%<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">ADJUSTMENT MODE<\/p>\n<p style=\"text-align: center;\">Reflector 250W JM: single ignition, no power regulation<br \/>\nDM 100W Series: 1-10V Dimming<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">LIFETIME<\/p>\n<p style=\"text-align: center;\">Reflector 250W JM: 8.000h<br \/>\nDM 100W Series: L70B20 50.000h<\/p>\n<p style=\"text-align: center; font-size: 18px;\">Difference: <strong>+42.000h<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"eut-empty-space eut-height-2x\" style=\"\"><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][vc_column_text]<\/p>\n<h2>Gas station relamping stazione di servizio with equal lighting values<\/h2>\n<p>[\/vc_column_text]<div class=\"eut-empty-space eut-height-1x\" style=\"\"><\/div>[vc_column_text]<\/p>\n<p style=\"text-align: left;\"><a href=\"https:\/\/www.luxi.lighting\/en\/?p=5121\" target=\"_blank\" rel=\"noopener\">CES-J 120W<\/a> vs REFLECTOR 2X54W HF T5<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]Gas station 20x50m and 7,4m high. The current installation foresees 35 luminaires at a height of 7m.<\/p>\n<p>Reflections: ceiling 70%, walls 50%, floors 20%. Height of the work surface at zero level.<\/p>\n<p>The simulation shows the effects of a replacement of the current halogen lights (2x54W HF T5 reflectors) with a number of <a href=\"https:\/\/www.luxi.lighting\/en\/?p=5121\" target=\"_blank\" rel=\"noopener\">120W CES-J<\/a> projectors such as to maintain the ground illuminance value of 150lux as required by the UNI EN 12464 standard.<br \/>\nNumber of LED projectors needed: 18 CES-J from 120W.[\/vc_column_text][\/vc_column][\/vc_row][vc_row bg_type=&#8221;image&#8221; bg_image=&#8221;5504&#8243; color_overlay=&#8221;dark&#8221; opacity_overlay=&#8221;50&#8243; font_color=&#8221;#ffffff&#8221;][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">LUMINAIRES NUMBER<\/p>\n<p style=\"text-align: center;\">Reflectors HF T5 2x54W: 35<br \/>\nCES-J 120W Series: 18<\/p>\n<p style=\"text-align: center; font-size: 18px;\">Difference:\u00a0<strong>-17<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">ILLUMINANCE VALUES<\/p>\n<p style=\"text-align: center;\">Reflectors HF T5 2x54W: 162lux<br \/>\nCES-J 120W Series: 184lux<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">TOTAL CONSUMPTION<\/p>\n<p style=\"text-align: center;\">Reflector HF T5 2x54W: 4 KWh<br \/>\nCES-J 120W Series: 2,13KWh<\/p>\n<p style=\"text-align: center; font-size: 18px;\">Difference: <strong>-46,75%<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">ADJUSTMENT MODE<\/p>\n<p style=\"text-align: center;\">Reflector HF T5 2x54W: single ignition, no power regulation<br \/>\nCES-J 120W Series: Dimming 1-10V<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/5&#8243; font_color=&#8221;#ffffff&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\">LIFETIME<\/p>\n<p style=\"text-align: center;\">Reflector HF T5 2x54W: 30.000h<br \/>\nCES-J 120W Series: L70B20 50.000h<\/p>\n<p style=\"text-align: center; font-size: 18px;\">Difference: <strong>+20.000h<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/4&#8243;][vc_column_text] Warehouse relamping with equal lighting values and equal number of light points [\/vc_column_text][vc_column_text] DM 100W vs REFLECTOR 250W JM [\/vc_column_text][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]Industrial warehouse of 50x50m and 6m height. The current installation includes 20 luminaires at a height of 5m from the ground. Reflections: ceiling 30%, walls 30%, floors 10%. Height of the work surface [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"cybocfi_hide_featured_image":"","footnotes":""},"class_list":["post-5517","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Case Study: Relamping - Luxi Illuminazione<\/title>\n<meta name=\"description\" content=\"Simulations and case studies aimed at showing the effects of a replacement of halogen lighting fixtures with LED fixtures such as to maintain equal illuminance values.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Case Study: Relamping - Luxi Illuminazione\" \/>\n<meta property=\"og:description\" content=\"Simulations and case studies aimed at showing the effects of a replacement of halogen lighting fixtures with LED fixtures such as to maintain equal illuminance values.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/\" \/>\n<meta property=\"og:site_name\" content=\"Luxi Illuminazione\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100063445637289#\" \/>\n<meta property=\"article:modified_time\" content=\"2019-01-14T09:16:49+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/case-study-relamping\\\/\",\"url\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/case-study-relamping\\\/\",\"name\":\"Case Study: Relamping - Luxi Illuminazione\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/#website\"},\"datePublished\":\"2019-01-14T09:16:48+00:00\",\"dateModified\":\"2019-01-14T09:16:49+00:00\",\"description\":\"Simulations and case studies aimed at showing the effects of a replacement of halogen lighting fixtures with LED fixtures such as to maintain equal illuminance values.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/case-study-relamping\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/case-study-relamping\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/case-study-relamping\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Case Study: Relamping\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/\",\"name\":\"Luxi Illuminazione\",\"description\":\"Corpi illuminanti LED per uffici, industria e outdoor\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/#organization\",\"name\":\"Luxi Illuminazione S.r.l.\",\"url\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.luxi.lighting\\\/wp-content\\\/uploads\\\/2018\\\/08\\\/logo_luxi_web.png\",\"contentUrl\":\"https:\\\/\\\/www.luxi.lighting\\\/wp-content\\\/uploads\\\/2018\\\/08\\\/logo_luxi_web.png\",\"width\":270,\"height\":80,\"caption\":\"Luxi Illuminazione S.r.l.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.luxi.lighting\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100063445637289#\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Case Study: Relamping - Luxi Illuminazione","description":"Simulations and case studies aimed at showing the effects of a replacement of halogen lighting fixtures with LED fixtures such as to maintain equal illuminance values.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/","og_locale":"en_US","og_type":"article","og_title":"Case Study: Relamping - Luxi Illuminazione","og_description":"Simulations and case studies aimed at showing the effects of a replacement of halogen lighting fixtures with LED fixtures such as to maintain equal illuminance values.","og_url":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/","og_site_name":"Luxi Illuminazione","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100063445637289#","article_modified_time":"2019-01-14T09:16:49+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/","url":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/","name":"Case Study: Relamping - Luxi Illuminazione","isPartOf":{"@id":"https:\/\/www.luxi.lighting\/en\/#website"},"datePublished":"2019-01-14T09:16:48+00:00","dateModified":"2019-01-14T09:16:49+00:00","description":"Simulations and case studies aimed at showing the effects of a replacement of halogen lighting fixtures with LED fixtures such as to maintain equal illuminance values.","breadcrumb":{"@id":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.luxi.lighting\/en\/case-study-relamping\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.luxi.lighting\/en\/case-study-relamping\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.luxi.lighting\/en\/"},{"@type":"ListItem","position":2,"name":"Case Study: Relamping"}]},{"@type":"WebSite","@id":"https:\/\/www.luxi.lighting\/en\/#website","url":"https:\/\/www.luxi.lighting\/en\/","name":"Luxi Illuminazione","description":"Corpi illuminanti LED per uffici, industria e outdoor","publisher":{"@id":"https:\/\/www.luxi.lighting\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.luxi.lighting\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.luxi.lighting\/en\/#organization","name":"Luxi Illuminazione S.r.l.","url":"https:\/\/www.luxi.lighting\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.luxi.lighting\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.luxi.lighting\/wp-content\/uploads\/2018\/08\/logo_luxi_web.png","contentUrl":"https:\/\/www.luxi.lighting\/wp-content\/uploads\/2018\/08\/logo_luxi_web.png","width":270,"height":80,"caption":"Luxi Illuminazione S.r.l."},"image":{"@id":"https:\/\/www.luxi.lighting\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100063445637289#"]}]}},"_links":{"self":[{"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/pages\/5517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/comments?post=5517"}],"version-history":[{"count":2,"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/pages\/5517\/revisions"}],"predecessor-version":[{"id":5519,"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/pages\/5517\/revisions\/5519"}],"wp:attachment":[{"href":"https:\/\/www.luxi.lighting\/en\/wp-json\/wp\/v2\/media?parent=5517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}